  applied power systems, inc. 124 charlotte avenue hicksville, ny 11801 ph: 516.935.2230 fax: 516.935.2603 website: www.appliedps.com page 1 of 6 rev. 120706 - 01 i ap200b120 sixpac? 200a / 1200v full - bridge igb t inverter features include multi - function power assembly compact size C 9 h x 17.60 w x 11.00 d dc bus voltages to 850vdc snubber - less operation to 650vdc switching frequencies to over 20khz protective circuitry with fail - safe opto - isolated fault annunciation, i ncluding: over current over voltage short circuit p.s. undervoltage over temperature opto - isolated or fiber - optic gate drive and fault signal output for electrical isolation and noise immunity integrated cooling with temperature sensors and feedback many options configurable power the sixpac ? is a flexible, highly integrated igbt based power assembly with a wide range of applications. these include inverters for motor controls, switch mode power supplies (smps), ups, welders, etc. the sixpac ? can be op erated at frequencies to over 20khz. the sixpac ? can be configured as a full bridge or three - phase bridge inverter mounted on an air - cooled or liquid - cooled heat sink. configurations include options for (full, half or no control) converter input circuitr y, inverter output circuitry, cooling and a wide variety of drivers and safety features for the converter front end and igbt inverter output stage. to operate at high switching frequencies, the sixpac ? utilizes a low inductance laminated bus structure, op tically isolated or fiber optically coupled gate drive interfaces, isolated gate power supplies and a dc - link capacitor bank. the sixpac ? provides built in protection features including: over voltage, under voltage lockout, over current, over temperature, short circuit and optional airflow or liquid flow indicators. flexibility is a key feature of the sixpac ? . options include: a choice of converter front ends, rectifier, half or full scr control, with or without scr gate firing boards and soft - start circ uitry. a choice of cooling methods, forced air or liquid is also available. customer provided pwm is optically coupled or a fiber optic link can be provided to the igbt interface. current feedback is provided by hall effect transducers. the sixpac ? i s rated to maximum input voltages up to 850 vdc, switching frequencies to over 20khz, includes many safety features to protect the igbts and output circuitry and can be configured to meet your application. schematic:
applied power systems, inc. 124 charlotte avenue hicksville, ny 11801 ph: 516.935.2230 fax: 516.935.2603 website: www.appliedps.com page 2 of 6 rev. 120706 - 01 i ap200b120 sixpac? 200a / 1200v full - bridge igb t inverter sixpac? i ap200b120 absolute maximum ratings C t j =25 c unless otherwise specified general symbol value units igbt junction temperature t j - 40 to +150 c storage temperature t stg - 40 to +125 c voltage applied to dc terminals v cc 850 volts isolation voltage, ac 1 minute, 60hz sinusoidal v iso 2500 volts igbt inverter collector current (t c =25 c) i c 200 amperes peak collector current (t j <150 c) i cm 400 amperes emitter current i e 200 amperes peak emitter current i em 400 amperes maximum collector dissipation (tj<150 c) p cd 890 watts gate drive board unregulated +24v power supply 30 volts regulated +15v power supply 18 volts pwm signal input voltage 20 volts fault output supply voltage 30 volts fault output current 50 ma igbt inverter electrical characteristics, t j =25 c unless ot herwise specified parameter symbol test conditions min typ max units collector cutoff current i ces v ce =v ces , v ge =0v - - 1 ma collector - emitter saturation voltage v ce(sat) i c =200a, t j =25 c - 1.8 2.4 volts i c =200a, t j =125 c - 1.9 - volts emitter - collec tor voltage v ec ie=200a - - 3.2 volts inductive load switching times t d(on) v cc =600v i c =200a v ge =15v r g =1.6? - - 300 s t r - - 80 s t d(off) - - 500 s t r - - 300 s diode reverse recovery time t rr - - 200 s diode reverse recovery charge q rr - 12.2 - c dc link capacitance - 4950 - f thermal and mechanical parameters parameter symbol test conditions min typ max units igbt thermal resistance, junction to case r (j - c) per igbt ? module - 0.08 0.15 c/w fwd thermal resistance, junction to case r (j - c) per fwd ? module - - 0.18 c/w heatsink thermal resistance r (s - a) 1500 lfm airflow - .0 45 - c/w mounting torque, ac terminals - 75 90 in - lb mounting torque, dc terminals - 130 150 in - lb mounting torque, case mounting - 130 150 in - lb weight - 21 - lb
applied power systems, inc. 124 charlotte avenue hicksville, ny 11801 ph: 516.935.2230 fax: 516.935.2603 website: www.appliedps.com page 3 of 6 rev. 120706 - 01 i ap200b120 sixpac? 200a / 1200v full - bridge igb t inverter gate drive board electrical characteristics parameter min typ max units unregulated +24v power supply 20 24 30 volts regulated +15v power supply 14.4 15 18 volts pwm input on threshold 12 15 - volts pwm inout off threshold - 0 2 volts output overcurrent trip - 300 - amperes overtemperature trip 8 6 8 8 9 0 c overvoltage trip - 900 - volts dc link voltage feedback see figure below volts heatsink temperature feedback see figure below volts output current feedback see figur e below volts dc link feedback 0 100 200 300 400 500 600 700 800 900 1000 0 1 2 3 4 5 6 7 8 9 10 feedback voltage (volts) dc link voltage (volts) heatsink temperature feedback 0 10 20 30 40 50 60 70 80 90 100 110 120 0 1 2 3 4 5 6 7 8 9 10 feedback voltage (volts) heatsink temperature (c) output current feedback -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 output feedback voltage (volts) output current (amps)
applied power systems, inc. 124 charlotte avenue hicksville, ny 11801 ph: 516.935.2230 fax: 516.935.2603 website: www.appliedps.com page 4 of 6 rev. 120706 - 01 i ap200b120 sixpac? 200a / 1200v full - bridge igb t inverter performance curves effective output current vs. carrier frequency (typical) conditions symbol value units ambient temperature t a 40 c dc bus voltage v cc 600 volts load power factor cos 0.8 igbt saturation voltage v ce(sat) typical @ t j =125 c volts igbt switching loss e sw typical @ t j =125 c mj airflow - 1500 lfm switching conditions single phase pwm, 60hz sinusoidal output options for the bap300t120 - xx option number option 01 02 03 04 05 06 07 08 09 blower x x x x x half - control scr converter x x full control scr conver ter x x diode converter x x dual inverter x x 200 amp full bridge sixpac? 40 50 60 70 80 90 100 110 50 60 70 80 90 100 110 120 130 140 150 output current rms heatsink temperature 10 khz 5 khz 1 khz ovt
applied power systems, inc. 124 charlotte avenue hicksville, ny 11801 ph: 516.935.2230 fax: 516.935.2603 website: www.appliedps.com page 5 of 6 rev. 120706 - 01 i ap200b120 sixpac? 200a / 1200v full - bridge igb t inverter interface pin # signal name description 1 shield connected to circu it ground 2 pwm a - 0 - 15v signal controlling the duty cycle of a - igbt 3 phase a error 1 open collector output, external pull - up resistor required. low=no error; floating=phase a overcurrent or short circuit 4 pwm a+ 0 - 15v signal controlling the duty cy cle of a+ igbt 5 pwm b - 0 - 15v signal controlling the duty cycle of b - igbt 6 phase b error 1 open collector output, external pull - up resistor required. low=no error; floating=phase a overcurrent or short circuit 7 pwm b+ 0 - 15v signal controlling the du ty cycle of b+ igbt 8 not used 9 not used 10 not used 11 overtemp 1 open collector output, external pull - up resistor required. low=no error; floating=heatsink overtemp 12 not connected 13 dc link voltage analog voltage representation of dc link voltage 14 24vdc input power 2 20 - 30vdc input voltage range 15 24vdc input power 2 20 - 30vdc input voltage range 16 15vdc input power 2 14.4 - 18vdc input voltage range 17 15vdc input power 2 14.4 - 18vdc input voltage range 18 gnd ground reference for 15 and 24vdc inputs 19 gnd ground reference for 15 and 24vdc inputs 20 heatsink temperature analog voltage representation of heatsink temperature 21 gnd 3 tied to pins 18 and 19 22 i out phase a analog voltage representation of phase a output current 23 gnd 3 t ied to pins 18 and 19 24 i out phase b analog voltage representation of phase b output current 25 not used 26 not used notes: 1. open collectors can be pulled up to 30vdc max and sink 50ma continuous. 2. do not connect a 15vdc and 24vdc source to the unit at the same time. use one or the other. 3. gnd signals to be used for analog feedback signals, i.e. twisted pair with i out phase a. gate drive interface connector description symbol type manufacturer gate drive interface header j1 0.100 x 0.100 latchin g header, 26 pin 3m #3429 - 6002 or equivalent recommending mating socket - 0.100 x 0.100 idc socket, 26 pin 3m #3399 - 7600 or equivalent recommended strain relief - plastic strain relief 3m #3448 - 3026 or equivalent
applied power systems, inc. 124 charlotte avenue hicksville, ny 11801 ph: 516.935.2230 fax: 516.935.2603 website: www.appliedps.com page 6 of 6 rev. 120706 - 01 i ap200b120 sixpac? 200a / 1200v full - bridge igb t inverter mechanical information


▲Up To Search▲   

 
Price & Availability of IAP200B120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X